| Manufacture | Other |
| Item No | CA901 |
| Article number | 144-901-000-282 |
| Series | Vibration |
| Origin | United States (US) |
| Dimension | 85*140*120(mm) |
| Weight | 0.6kg |
| Customs Tariff Number | 85389091 |
| Type | Piezoelectric Accelerometer |
OPERATING (at +23°C ±5°C) Sensitivity (at 120 Hz) : 10 pC/g ±5% Dynamic measuring range (random) : 0.001 g to 200 g peak Overload capacity (spikes) : Up to 500 g peak Linearity : ±1% over dynamic measuring range Transverse sensitivity : < 5% Resonance frequency (mounted) : > 17 kHz nominal Frequency response • 3 to 2800 Hz nominal : ±5% (lower cutoff frequency is determined by the electronics used) • 2800 to 3700 Hz : < 10% Internal insulation resistance : Min. 109 Ω Capacitance (nominal) • Pole to pole : 80 pF for transducer + 200 pF/m of cable • Pole to casing : 18 pF for transducer + 300 pF/m of cable